Quality Control Processes for Manufacturing LED Red Light Therapy Devices

ShineNova Quality Control for LED Red Light Therapy Devices

A top-of-the-line LED red light therapy device means excellent performance, high quality, and stable use for many years. However, from the perspective of red light therapy manufacturers and factories, this is not easy to achieve because it means high manufacturing costs and increased quality control processes, which require the purchase of high-quality raw materials, increased rework, and scrapping of defective products.

We understand the complexity of international trade and the challenges of business, so ShineNova adheres to three core values: innovation, quality, and customer satisfaction. We are committed to providing our clients with top-of-the-line LED red light therapy devices to help people regain their health and support our customers’ business success and smooth sales operations. For purchasers and importers of red light therapy devices, quality is a critical consideration. They typically start by ordering samples and only proceed with bulk purchases of red light therapy products after confirming the quality of the samples.

Many people are unaware that the quality control process for LED red light therapy devices during production is highly complex, as it involves multiple areas such as electrical safety, optical performance, and structural reliability. The quality control of LED red light therapy devices is a systematic process that encompasses every step from design verification, raw material procurement, incoming material inspection, production process, pre-shipment testing, to after-sales feedback. The objective is to ensure that the devices comply with safety standards, performance requirements, customer expectations, and relevant regulations.

For example, safety testing must comply with certification standards in the sales region, which vary significantly by country. The importance of aging tests, as many issues only surface after prolonged power supply, electromagnetic compatibility must also be considered. Quality control is not limited to testing, it begins with supplier management. For instance, the high brightness of LED light sources and the stability of power supplies—these critical components must be rigorously controlled from the supplier source. The following are the key stages of quality control for the top red light therapy devices:

ShineNova used high brightness LED chips and 30-degree optical lens

ShineNova used high brightness LED chips and 30-degree optical lens

Design and Development

Design Review

Ensure that the design meets the safety standards (e.g., IEC/EN, UL, ETL, EMC, LVD, etc.), performance requirements (high irradiance values, precise wavelength), cost targets, and manufacturability of the target market.

 

Design Verification

Critical Raw Material Selection: Verify that the selected critical components (e.g., LED light source, driver power supply, housing material, connectors) possess the required certifications and reliability data.

Prototype Manufacturing and Testing: Manufacture LED phototherapy device samples for comprehensive functional and performance testing.

Safety Testing: Conduct electrical testing in accordance with safety standards of the target market (e.g., insulation withstand voltage, ground resistance, electrical clearance, temperature rise, abnormal testing, etc.).

Optical Simulation and Actual Measurement: Use an integrating sphere or spectrometer to measure the actual optical parameters, such as irradiance and wavelength, of the samples.

Structural Reliability Assessment: Evaluate structural strength, heat dissipation, mounting hole positions, and ease of installation.

ShineNova Integrating Sphere test

Integrating Sphere Test

Design Validation

Conduct small-scale pilot production before final design approval to verify the feasibility of production processes and quality stability.

 

Incoming Material Quality Control

Supplier Management

Evaluate and select good suppliers and establish long-term business relationships with them.

ShineNova IQC Parameter test of supplier's incoming power supply

ShineNova IQC Parameter test of supplier’s incoming power supply

Incoming Material Inspection

Inspection Standard Formulation: Formulate detailed incoming material inspection specifications based on QC personnel requirements and relevant standards.

Supplier Incoming Material Inspection: Conduct sampling inspections or full inspections following internationally recognized standards. Reject any nonconforming products.

Inspection Items:

Critical Components: Verify model specifications, appearance, dimensions, and critical parameter testing (e.g., power output voltage and current, LED chip wavelength).

Housing: Appearance (scratches, burrs, deformation, color differences), dimensions, material.

Packaging Materials: Paper strength, print clarity.

Testing: Includes basic electrical testing (e.g., continuity), material flame resistance testing (glow wire), salt spray testing (metal parts), etc.

The following is the ShineNova silicone LED face mask steel mold, used to make the SNM7 LED Face mask. The SNM9 hollowed-out LED face mask and SNM8 red light therapy mask use a more complicated mold.

ShineNova silicone LED face mask steel mold

ShineNova silicone LED face mask steel mold

Non-conforming Product Handling

Non-conforming materials are labeled, isolated, and suppliers are notified via established procedures to arrange for replacement or disposal.

 

Production Process Quality Control

Initial Product Inspection

After a production line changeover, equipment adjustment, or the start of mass production, the first few units of LED red light therapy products produced are subjected to comprehensive inspection and testing to confirm compliance with requirements before proceeding with formal mass production.

ShineNova LED SMT Machine

ShineNova LED SMT Machine

Process Inspection

Operator Self-Inspection: Operators are trained and instructed to conduct basic visual and functional inspections, reporting any issues promptly.

IPQC Patrol Inspections: Process quality control personnel conduct regular or irregular patrol inspections of the production line to check:

Whether operators are following the work instructions.

Whether the equipment parameters are correctly set.

Whether the tooling and fixtures are in good condition.

Randomly select work-in-progress red light therapy devices for appearance and critical functional inspections. The following is the assembly workshop of the SN1500 1500W red light therapy panel.

ShineNova Red Light Therapy Panel Assembly Line

ShineNova Red Light Therapy Panel Assembly Line

Critical Process Monitoring

Welding Quality: Visually inspect or use a magnifying glass or AOI to check for weld point fullness, cold welds, cold solder joints, and solder bridges.

Screw Tightening: Use a wrench to monitor whether screws are properly tightened and the overall structural integrity of the assembled device.

Adhesive Sealing: Monitor adhesive quantity, mixing ratio, curing time, and temperature to ensure stability.

Aging Test: Perform a power-on aging test on the fully assembled LED red light therapy panel for a certain period (e.g., 8–12 hours) to simulate initial use and identify early failure products (e.g., power supply failures, dead LEDs, poor contact, etc.).

Functional Testing: Typically conducted as part of the aging test or final testing, this involves checking basic functions such as switch operation, dimming brightness, frequency adjustment, and remote control signal reception.

Safety Testing: High-voltage testing, ground continuity testing.

Basic Electrical Parameter Testing: Input power, power factor, current, etc.

ShineNova Finished Product Function Testing

ShineNova Finished Product Function Testing

Environmental Management

Control production environment ESD (electrostatic discharge protection), temperature and humidity, and cleanliness (especially for optical components).

 

Finished Product Quality Control

Final Inspection

100% Visual Inspection: Inspect the overall appearance of the red light therapy device for damage, dirt, scratches, incorrect or missing labels, poor assembly, etc.

100% Functional Inspection: Repeat basic functional tests (e.g., power switch, dimming, etc.).

ShineNova high quality of finished panel

ShineNova high quality of finished panel

Sampling Inspection

Performance Testing: Select a certain proportion of finished products for more comprehensive performance testing, such as irradiance values, etc.

Structural Inspection: Disassemble and inspect internal wiring, component fixation, cooling fans, and the durability of printed logos etc.

Packaging Inspection: Inspect packaging integrity, completeness of manuals and accessories, and drop testing (simulating transportation).

Reliability Testing: In a laboratory environment, conduct simulated harsh environment or long-term use tests on representative samples to assess product lifespan and reliability.

Environmental Testing: High-temperature aging, low-temperature startup and operation, temperature cycling.

Mechanical Testing: Vibration testing, impact testing, drop testing.

Material Aging Testing: Evaluate the UV resistance, yellowing resistance, and weather resistance of plastic casings, films, and other materials.

Safety Testing and Maintenance: Ensure that mass-produced products consistently meet relevant safety, electromagnetic compatibility, and other certification requirements.

The following is the ShineNova red light therapy mat test, which is suitable for the SNP1200 red light therapy mat, the SNP1300 red light therapy blanket, the SNP2200 red light therapy pod, and the SNP2500 red light therapy sleeping bag.

ShineNova red light therapy mat test

ShineNova red light therapy mat test

Shipping and After-Sales Feedback

Shipping Review

Confirm that all inspections and tests have been completed and passed, and that packaging meets requirements.

ShineNova Finished Product Packing

ShineNova Finished Product Packing

Warehouse Management

Control the storage environment (temperature, humidity, and dust prevention) of the finished goods warehouse.

 

Customer Feedback and Return Analysis

Sales representatives collect customer complaints and feedback.

Engineers analyze the causes of defective products.

Feedback the analysis results to R&D, procurement, production, and other departments to drive continuous improvement.

 

Quality Data Statistics and Analysis

Collect quality data from all stages (defect rate, defect types, test results), conduct statistical analysis, and identify key issues and improvement opportunities.

 

A robust and strictly enforced quality control process is the key to ShineNova, a Chinese red light therapy device manufacturer and factory, gaining trust in overseas markets, ensuring end-user safety, enhancing company reputation, and reducing quality risks.

The quality control success core points can be summarized as follows: source control (during the design phase and selection of raw material suppliers) is important. All inspections and tests have clear, enforceable standards (international and industry standards, customer requirements, and internal regulations). Combining on-site testing, sampling testing, and aging testing to verify product quality from multiple dimensions. Continuous improvement: Utilizing quality data analysis and customer feedback to drive ongoing optimization of processes and products.

Facebook
Twitter
LinkedIn
Reddit
Threads

About ShineNova

ShineNova is a manufacturer and exporter of red light therapy devices based in Shenzhen, China. We specialize in the wellness and beauty industry, boasting over 10 years of experience in design, research and development, production, and sales. Our red light therapy devices have been exported to more than 100 countries and regions. Additionally, we offer ODM and OEM customized services for numerous major companies and brands.